Hygrothermal performance of heritage masonry retrofitted with lime hemp interior insulation: a monitoring campaign
Abstract
This study presents the monitoring results for solid masonry internally insulated with lime hemp blocks in combination with loose lime hemp filling. A drying out of the moisture in the loose lime hemp is found to occur very slowly. The high moisture conditions in the lime hemp together with a reduced actual insulation thickness of the lime hemp blocks, due to a.o. the penetration of the interior plaster in the insulation blocks, yields a rather low improvement of the walls’ thermal performance.Keywords: interior insulation, monitoring campaign, hygrothermal performance, lime hemp, heritage masonry
How to Cite:
Evy, V., Roels, S. & Stappers, M., (2025) “Hygrothermal performance of heritage masonry retrofitted with lime hemp interior insulation: a monitoring campaign”, UCL Open Environment 7(S1). doi: https://doi.org/10.14324/111.444/ucloe.icmb25.a12
Rights: Author, [2025]